AS/NZS 3001:2022 Explained
Last updated: November 2026
Library Navigation Menu
Understanding electrical safety requirements for caravans, motorhomes, campervans, caravan plugs, shore leads and connectable electrical installations in New Zealand.
Caravans and motorhomes are regularly connected to external power supplies at holiday parks, camping grounds and other locations.
The electrical connection is commonly referred to as a caravan lead, caravan power lead, hook-up lead or shore lead. Whatever the name, it plays an important role in supplying electricity safely to the vehicle.
Because these leads are frequently handled, transported and used outdoors, they can be exposed to physical damage, moisture, dirt and deterioration.
The AS/NZS 3001:2022 series establishes requirements for electrical supplies and connectable electrical installations, while AS/NZS 3760:2022 provides a framework for in-service safety inspection and testing of applicable electrical equipment.
Understanding the difference between these standards helps caravan owners, camping ground operators and electrical testing providers recognise their responsibilities.
Understanding AS/NZS 3001.1 and AS/NZS 3001.2
The AS/NZS 3001:2022 series is divided into two parts.
AS/NZS 3001.1:2022 – Site Supplies
Part 1 covers electrical supply arrangements for connectable electrical installations.
These include electrical supply systems commonly used at caravan parks, holiday parks and camping grounds.
The standard addresses matters such as:
-
Electrical supply outlets and connection arrangements.
-
Appropriate electrical protection, including residual current devices (RCDs).
-
Installation and protection of electrical supply equipment.
-
Electrical safety in outdoor and exposed environments.
-
Requirements for supplying connectable electrical installations.
The site supply is a separate electrical installation from the caravan or motorhome connected to it.
AS/NZS 3001.2:2022 – Connectable Electrical Installations
Part 2 addresses the electrical installation within caravans, motorhomes, campervans and other applicable connectable installations.
Its requirements cover areas such as:
-
Electrical wiring and installation arrangements.
-
Connection to external electrical supplies.
-
Earthing and electrical protection.
-
Electrical equipment installed within the vehicle.
-
Relevant battery system and electrical safety requirements.
-
Inspection, testing and verification.
This distinction is important because testing a detachable caravan lead does not establish that the electrical installation inside the vehicle is compliant.
Caravan Power Leads and Power Connections
A caravan power lead connects the vehicle's electrical inlet to an external power supply.
In New Zealand, these connections commonly use suitable industrial-style plugs and connectors rather than ordinary domestic extension lead fittings.
A suitable caravan lead must be appropriate for its intended application, including its electrical rating, construction, connector arrangement and environmental conditions.
Common Shore Lead Safety Concerns
Regular handling and outdoor use can contribute to:
-
Cuts, abrasions or damage to cable insulation.
-
Cracked caravan plugs or socket connectors.
-
Loose, damaged or overheated electrical contacts.
-
Corrosion or moisture contamination.
-
Damaged cable entry points or strain relief.
-
Incorrectly assembled or unsuitable replacement connectors.
-
Mechanical damage from vehicles or equipment.
A lead that appears satisfactory externally may still have an electrical fault that requires appropriate testing to identify.
Safe Use of Caravan Power Leads
Good electrical safety practices include:
-
Using suitable plugs, connectors and cables designed for the intended supply.
-
Keeping the lead in one continuous length without joining multiple extension leads together.
-
Fully uncoiling the lead before use.
-
Protecting it from vehicle traffic, sharp edges and physical damage.
-
Keeping connectors away from standing water.
-
Disconnecting and removing damaged equipment from service.
-
Following the manufacturer's instructions and applicable electrical safety requirements.
-
Understanding IP Ratings on Caravan Plugs and Connectors
Electrical plugs, sockets and connectors may display an IP rating, meaning Ingress Protection.
An IP rating indicates the level of protection provided by an enclosure against the entry of solid objects and water.
The first digit relates to protection against solid objects and dust. The second digit relates to protection against water.
Common IP Rating Examples
IP44 - Protected against solid objects larger than 1 mm and splashing water from any direction.
IP55 - Dust-protected and protected against water jets.
IP67 - Dust-tight and protected against temporary immersion under specified conditions.
Why IP Ratings Matter
Caravan electrical connections may be exposed to rain, splashing water, dust and changing weather conditions.
An appropriate IP rating helps reduce the risk of moisture or contamination entering the connector.
However, a higher IP rating does not automatically mean a plug is suitable for every application.
Electrical rating, connector compatibility, installation requirements and the conditions under which the IP rating applies must also be considered.
For example, a connector may only achieve its stated protection when correctly mated, assembled or fitted with its protective cap.
Important: The appropriate IP rating must be determined from the applicable standard, connector specifications and intended installation conditions. IP44, IP55 and IP67 are examples, not universal minimum requirements for all caravan shore leads.
AS/NZS 3760:2022 – Inspection and Testing of Electrical Equipment
AS/NZS 3760:2022 addresses the in-service safety inspection and testing of electrical equipment within its scope.
For detachable caravan shore leads, it provides a useful testing framework where applicable, alongside the specific requirements of AS/NZS 3001 and New Zealand electrical safety legislation.
Inspection and testing may include:
-
Visual examination of the flexible cable.
-
Inspection of plugs, sockets and connector housings.
-
Checking for damage, deterioration or overheating.
-
Protective earth continuity testing.
-
Insulation resistance testing.
-
Verification of conductor connections and polarity, as appropriate.
The inspection and testing method must be suitable for the particular lead and applicable requirements.
Is Caravan Lead Testing the Same as an Electrical Warrant of Fitness?
No. A detachable shore lead inspection or test is not the same as an Electrical Warrant of Fitness (EWOF or WoEF).
An Electrical Warrant of Fitness concerns the safety of the connectable electrical installation and is issued under the applicable New Zealand electrical safety requirements.
A current EWOF is generally valid for four years from the date of issue.
Testing a caravan lead does not replace an EWOF or certify the caravan's internal wiring, RCDs or other installed electrical systems.
Electrical Safety Requirements in New Zealand
Electrical safety requirements are established under the Electricity Act 1992 and the Electricity (Safety) Regulations 2010.
Amendments that came into effect on 13 November 2025 updated the cited versions of AS/NZS 3001.1 and AS/NZS 3001.2, subject to specific New Zealand modifications and applicable transitional provisions.
The relevant requirements depend on whether the work involves:
-
A caravan park or camping ground electrical supply.
-
The electrical installation inside a caravan or motorhome.
-
A detachable caravan power lead.
-
Inspection, testing, maintenance or certification.
Electrical installation work and certification must be undertaken by appropriately authorised personnel where required.
How MegaTest Can Help With Caravan & Shore Lead Testing
MegaTest, a division of NZ Test Group Ltd, provides electrical equipment safety inspection and testing services in Christchurch and throughout the wider South Island.
Our services include inspection and electrical safety testing of suitable detachable caravan and motorhome shore leads.
Testing helps identify potential safety concerns and provides a documented record of the inspection and results.
Where defects are identified, these are reported so the equipment can be removed from service until appropriately repaired or replaced.
MegaTest's detachable shore lead testing service does not include issuing Electrical Warrants of Fitness or certifying the caravan's internal electrical installation.
Caravan Power Leads vs Marine Shore Leads
Although both caravans and boats may connect to an external electrical supply using a shore lead, their electrical requirements are not identical.
Caravan and motorhome electrical installations are covered by the applicable AS/NZS 3001 requirements.
Marina supplies and relevant boat electrical installations are addressed by the AS/NZS 3004 series.
Marine environments introduce additional considerations, including saltwater exposure, corrosion, connector suitability and the specific requirements for electrical connections at marinas.
A caravan plug or lead should not automatically be considered suitable for a marine application, or vice versa.
Understanding which standard applies is just as important as carrying out the testing itself.
References and Further Reading of our Plain English Guides and Blog Articles
-
AS/NZS 3760:2022 – In-service safety inspection and testing of electrical equipment.
-
Electricity (Safety) Regulations 2010, including applicable amendments.
Official New Zealand guidance
This page provides general guidance only and does not replace applicable legislation, standards or advice from an appropriately authorised electrical professional.
Need Help With AS/NZS 3001?
MegaTest – Appliance Electrical Testing
MegaTest provides electrical equipment inspection, testing and compliance solutions as part of NZ Test Group.
If you're unsure what inspection or testing requirements apply to your caravan, motorhome or shore lead, talk to our team.