Fire Extinguisher Selection & Use – NZ Guide
Library Navigation Menu
Last updated: October 2026
Choosing the correct fire extinguisher is an important part of workplace fire safety. Different types of fires require different extinguishing agents, and using the wrong extinguisher can make a dangerous situation worse.
Fire and Emergency New Zealand recommends that commercial premises have suitable firefighting equipment available, particularly where workplace activities present increased fire risks.
Understanding fire classes, extinguisher types and safe operating procedures helps businesses make informed decisions about their fire protection equipment.
Understanding Fire Classes in New Zealand
Fires are classified according to the materials or hazards involved.
-
Class A – Ordinary combustible materials: Wood, paper, textiles and certain plastics.
-
Class B – Flammable liquids: Petrol, solvents, paints and similar liquids.
-
Class C – Flammable gases: LPG, butane and other combustible gases.
-
Class D – Combustible metals: Magnesium, titanium and certain other metals.
-
Class E – Electrically energised equipment: Fires involving live electrical equipment, wiring and switchboards.
-
Class F – Cooking oils and fats: Deep fryers and other cooking equipment containing oils or fats.
The fire class helps determine which extinguishing agent is appropriate.
Common Types of Fire Extinguishers
ABE Dry Powder Extinguishers
ABE dry powder extinguishers are commonly used in New Zealand workplaces.
They are suitable for several fire classes, including ordinary combustible materials, flammable liquids and electrically energised equipment.
They are often found in offices, workshops, vehicles and general commercial environments.
However, dry powder can leave considerable residue and may damage sensitive equipment.
ABE dry powder extinguishers should not be used on cooking oil or fat fires.
Carbon Dioxide (CO₂) Extinguishers
Carbon dioxide extinguishers are commonly used where electrical equipment is present.
They discharge without leaving the powder residue associated with dry chemical extinguishers.
Typical locations include electrical equipment rooms and areas containing sensitive electronic equipment.
CO₂ extinguishers have limitations, including reduced effectiveness outdoors or in windy conditions and the potential for re-ignition.
Water Extinguishers
Water extinguishers are primarily intended for Class A fires involving ordinary combustible materials.
They are not suitable for fires involving live electrical equipment, flammable liquids or cooking oils and fats.
Foam Extinguishers
Foam extinguishers are commonly used for Class A and Class B fire risks, depending on the extinguisher's specific rating.
They may be appropriate where combustible solids and certain flammable liquids are present.
Standard foam extinguishers should not be used on live electrical equipment unless the specific product is approved and labelled for that application.
Wet Chemical Extinguishers
Wet chemical extinguishers are designed particularly for Class F fires involving cooking oils and fats.
They are commonly used in commercial kitchens and areas containing deep fryers.
They should not be substituted with a general-purpose ABE extinguisher when protecting cooking oil hazards.
Specialist Extinguishers
Some workplaces have hazards requiring specialist extinguishing agents.
For example, Class D combustible metal fires require extinguishers specifically designed for the metals involved.
These situations should be assessed individually, with specialist advice where necessary.
Choosing the Right Extinguisher for Your Workplace
Selecting extinguishers should begin with an assessment of the fire risks present.
Consider:
-
The materials, equipment and substances used or stored.
-
The types of fires that could reasonably occur.
-
The extinguisher's fire-class suitability and performance rating.
-
The size and layout of the premises.
-
Safe access, visibility and positioning.
-
Whether workers have appropriate training.
A workplace may need more than one extinguisher type to address different hazards.
For example, an office with electrical equipment and a commercial kitchen may require different extinguishing agents in each area.
Are Fire Extinguishers Mandatory in Every Workplace?
Not necessarily. Fire and Emergency New Zealand strongly recommends providing suitable fire extinguishers or hose reels in commercial premises.
However, specific legal requirements can apply depending on the building, its use and the hazards present.
For example, workplaces storing certain quantities of hazardous substances may be required to provide a specified number of suitable fire extinguishers under the Health and Safety at Work (Hazardous Substances) Regulations 2017.
Businesses should assess their particular circumstances rather than assume one rule applies to every workplace.
Where Should Fire Extinguishers Be Located?
Fire extinguishers should be readily accessible, clearly identifiable and positioned where they can be reached safely.
Suitable locations may include:
-
Near normal access routes and exits.
-
Close to identified fire hazards, but at a safe distance.
-
Areas where workers can readily see and access the equipment.
Extinguishers should not be obstructed by stored goods, furniture or other equipment.
Placement, installation and distribution should be assessed against applicable requirements, including NZS 4503:2005.
When Is It Safe to Use a Fire Extinguisher?
Personal safety and evacuation must always come first.
Fire and Emergency New Zealand advises that extinguishers should only be used when:
-
The fire is small and contained.
-
The correct extinguisher is available.
-
The person understands how to operate it.
-
The alarm has been raised, evacuation is underway, and everyone in the immediate danger area is moving to safety.
-
Fire and Emergency New Zealand has been called.
-
A clear and safe escape route remains available.
If the fire is spreading, producing significant smoke or cannot be controlled immediately, leave the area.
Never place yourself or others at risk to protect property.
How to Operate a Fire Extinguisher
Fire and Emergency New Zealand recommends the PTASS method:
-
P – Pull: Remove the safety pin or clip.
-
T – Test: Give a short test discharge to confirm the extinguisher operates.
-
A – Aim: Direct the nozzle towards the base of the fire from a safe distance.
-
S – Squeeze: Squeeze the operating handles.
-
S – Sweep: Move the discharge from side to side across the base of the fire.
Always follow the extinguisher manufacturer's operating instructions and any relevant workplace training.
Inspection and Maintenance of Fire Extinguishers
Selecting the right extinguisher is only part of maintaining effective fire protection.
Extinguishers should also be kept in suitable condition, with regular inspection and maintenance in accordance with applicable requirements.
In New Zealand, NZS 4503:2005 provides guidance and requirements for the selection, installation, distribution and maintenance of hand-operated firefighting equipment.
Routine servicing helps identify issues such as damage, missing safety seals, incorrect pressure, blocked discharge components and equipment requiring further attention.
For more information, see our Fire Extinguisher Inspection & Maintenance guide in the NZ Test Group Knowledge Library.
How FireTest Supports Workplace Fire Safety
FireTest, part of NZ Test Group, provides fire equipment inspection and compliance solutions for New Zealand businesses.
Our work helps businesses maintain their fire extinguishers and associated equipment, identify servicing issues and maintain appropriate inspection records.
Extinguisher selection, installation, staff training and emergency procedures should also be considered as part of a workplace's wider fire safety arrangements.
Official New Zealand Guidance
For further information, refer to:
Fire and Emergency NZ – Commercial Use of Fire Extinguishers
Fire and Emergency NZ – Fire Extinguishers and Safe Operation
WorkSafe NZ – Hazardous Substances Emergency Plans
Need Help With Fire Equipment Compliance?
NZ Test Group can assist with fire equipment inspection and maintenance through FireTest.
Our services help businesses identify equipment-related safety issues and maintain appropriate servicing records.
If you're unsure which fire extinguisher inspection or maintenance requirements apply to your workplace, talk to our team.